Aquifer thermal energy storage : A well doublet experiment at increased temperatures

View/ Open
Issue Date
1983-02Author
Molz, F. J.
Melville, J. G.
Parr, Alfred D.
King, D. A.
Hopf, M. T.
Publisher
American Geophysical Union
Type
Article
Article Version
Scholarly/refereed, publisher version
Metadata
Show full item recordAbstract
The two main objectives of this communication are to present a study of potential advantages and disadvantages of the doublet supply-injection well configuration in an aquifer thermal energy storage (ATES) system and to report on aquifer storage problems with injection temperatures in the 80°C range. A 3-month injection-storage-recovery cycle followed by a 7.3-month cycle constituted the main experiment. The injection volumes were 25,402 m3 and 58,063 m3 at average temperatures of 58.5°C and 81°C respectively. Unlikely previous experiments at the Mobile site, no clogging of the injection well due to clay particle swelling, dispersion, and migration was observed. This is attributed to the fact that the supply water used for injection contained a cation concentration equal to or slightly greater than that in the native groundwater. For cycles I and II, the fraction of injected energy recovered in a volume of water equal to the injection volume was 0.56 and 0.45 respectively. Both groundwater temperature and tracer data support the conclusion that this relatively low recovery was due to the detrimental effects of free thermal convection, possibly augmented by longitudinal zones of high permeability. Construction of a partially penetrating recovery well improved recovery efficiency but is not thought to be an adequate solution to thermal stratification. A maximum increase of 1.24 cm in relative land surface elevation was recorded near the end of second cycle injection. The engineering implications of such an elevation change would have to be considered, especially if an ATES system were being designed in an urban environment. A third cycle was started at the Mobile site on April 7, 1982. This final experiment contains a partially penetrating, dual-recovery well system which is expected to maximize energy recovery from a thermally stratified storage aquifer.
Description
This is the published version. Copyright 1983 American Geophysical Union
Collections
Citation
Molz, F. J., J. G. Melville, A. D. Parr, D. A. King, and M. T. Hopf. "Aquifer Thermal Energy Storage : A Well Doublet Experiment at Increased Temperatures." Water Resources Research Water Resour. Res. 19.1 (1983): 149-60. http://dx.doi.org/10.1029/WR019i001p00149
Items in KU ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
We want to hear from you! Please share your stories about how Open Access to this item benefits YOU.