dc.identifier.citationR.P. Buck, S. Rondinini, A.K. Covington, F.G.K. Baucke, C.M.A. Brett, M.F. Camões, M.J.T. Milton, T. Mussini, R. Naumann, K.W. Pratt, R. Spitzer, and G.S. Wilson, Measurement of pH. Definition, Standards, and Procedures, Pure and Applied Chemistry, 74, 2169-2200 (2002).
dc.identifier.urihttp://hdl.handle.net/1808/8412
dc.description.abstractThe definition of a “primary method of measurement” [1] has permitted a full consideration of the definition of primary standards for pH, determined by a primary method (cell without transference, Harned cell), of the definition of secondary standards by secondary methods, and of the question whether pH, as a conventional quantity, can be incorporated within the internationally accepted system of measurement, the International System of Units (SI, Système International d’Unités). This approach has enabled resolution of the previous compromise IUPAC 1985 Recommendations [2]. Furthermore, incorporation of the uncertainties for the primary method, and for all subsequent measurements, permits the uncertainties for all procedures to be linked to the primary standards by an unbroken chain of comparisons. Thus, a rational choice can be made by the analyst of the appropriate procedure to achieve the target uncertainty of sample pH. Accordingly, this document explains IUPAC recommended definitions, procedures, and terminology relating to pH measurements in dilute aqueous solutions in the temperature range 5–50 °C. Details are given of the primary and secondary methods for measuring pH and the rationale for the assignment of pH values with appropriate uncertainties to selected primary and secondary substances.
dc.language.isoen_US
dc.publisherInternational Union of Pure and Applied Chemistry
dc.relation.isversionofhttp://www.iupac.org/publications/pac/pdf/2002/pdf/7411x2169.pdf
dc.titleMeasurement of pH. Definition, Standards, and Procedures
dc.typeArticle
kusw.kuauthorWilson, George S.
kusw.kudepartmentChemistry
kusw.oastatusfullparticipation
kusw.oaversionScholarly/refereed, publisher version
kusw.oapolicyThis item meets KU Open Access policy criteria.
dc.rights.accessrightsopenAccess


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record