ATTENTION: The software behind KU ScholarWorks is being upgraded to a new version. Starting July 15th, users will not be able to log in to the system, add items, nor make any changes until the new version is in place at the end of July. Searching for articles and opening files will continue to work while the system is being updated. If you have any questions, please contact Marianne Reed at mreed@ku.edu .

Show simple item record

dc.contributor.authorSeliem, Hatem M.
dc.contributor.authorHosny, Amr
dc.contributor.authorRizkalla, Sami
dc.contributor.authorZia, Paul
dc.contributor.authorBriggs, Michael
dc.contributor.authorMiller, Shelby
dc.contributor.authorDarwin, David
dc.contributor.authorBrowning, JoAnn
dc.contributor.authorGlass, Gregory M.
dc.contributor.authorHoyt, Kathryn
dc.contributor.authorDonnelly, Kristen
dc.contributor.authorJirsa, James O.
dc.date.accessioned2021-02-03T16:16:35Z
dc.date.available2021-02-03T16:16:35Z
dc.date.issued2009-07
dc.identifier.citationSeliem, H. M., Hosny, A., Rizkalla, S., Zia, P., Briggs, M., Miller, S., Darwin, D., Browning, J., Glass, G. M., Hoyt, K., Donnelly, K., and Jirsa, J. O., “Bond Characteristics of High-Strength ASTM A1035 Steel Reinforcing Bars,” ACI Structural Journal, Vol. 106, No. 4, July-Aug. 2009, pp. 530-539.en_US
dc.identifier.urihttp://hdl.handle.net/1808/31330
dc.description.abstractThe results of a coordinated research program on the bond characteristics of the high-strength steel reinforcing bars that conform to ASTM A1035 are presented. Concrete with nominal strengths of 5000 and 8000 psi (35 and 55 MPa) were used. Sixtynine large-scale beam-splice specimens were tested. Maximum bar stresses are compared with predictions obtained using the bond equations in the ACI 318-05 code provisions and those proposed by ACI Committee 408. Maximum stress levels of 120, 110, and 96 ksi (830, 760, and 660 MPa) were developed in No. 5, No. 8, and No. 11 (No. 16, No. 25, and No. 36) bars, respectively, not confined by transverse reinforcement. Providing confinement for No. 8 and No. 11 (No. 25 and No. 36) spliced bars using transverse reinforcement allowed stresses of up to 150 ksi (1035 MPa) to be developed. The ACI Committee 408 equation provides a reasonable estimate of the strength for both unconfined and confined splices using a strength reduction factor (f-factor) of 0.82 and design parameters (cover, spacing, and concrete strengths) comparable to those used in this test program. The design equations in ACI 318 are less conservative, with a large percentage of the developed/calculated strength ratios below 1.0, and should not be used for development and splice design with high-strength reinforcing steel in their present form.en_US
dc.publisherAmerican Concrete Instituteen_US
dc.relation.isversionofhttps://iri.ku.edu/papersen_US
dc.rightsCopyright © 2009, American Concrete Institute. All rights reserved, including the making of copies unless permission is obtained from the copyright proprietors. Pertinent discussion including author’s closure, if any, will be published in the May-June 2010 ACI Structural Journal if the discussion is received by January 1, 2010.en_US
dc.titleBond Characteristics of ASTM A1035 Steel Reinforcing Barsen_US
dc.typeArticleen_US
kusw.kuauthorDarwin, David
kusw.kuauthorBrowning, JoAnn
kusw.kudepartmentCivil, Environmental, and Architectural Engineeringen_US
kusw.oastatusna
dc.identifier.doi10.14359/56619en_US
dc.identifier.orcidhttps://orcid.org/0000-0001-5039-3525en_US
kusw.oaversionScholarly/refereed, publisher versionen_US
kusw.oapolicyThis item meets KU Open Access policy criteria.en_US