Show simple item record

dc.contributor.authorSperry, Jayne
dc.contributor.authorDarwin, David
dc.contributor.authorO’Reilly, Matthew
dc.contributor.authorLequesne, Rémy D.
dc.date.accessioned2016-03-07T19:01:55Z
dc.date.available2016-03-07T19:01:55Z
dc.date.issued2015-12
dc.identifier.citationSperry, J., Darwin, D., O'Reilly, M., and Lequesne, R., "Anchorage Strength of Conventional and High-Strenth Hooked Bars in Concrete," SM Report No. 115, The University of Kansas Center for Research, Inc., Lawrence, KS, December 2015, 281 pp.en_US
dc.identifier.urihttp://hdl.handle.net/1808/20476
dc.description.abstractKey factors affecting the anchorage strength of hooked bars are investigated and design guidelines for the development length of hooked bars that apply to both conventional and highstrength steel and concrete are presented. In this study, 337 beam column joint specimens were tested. Parameters included number of hooks (2, 3, or 4), concrete compressive strength (4,300 to 16,510 psi [30 to 114 MPa]), bar stress at failure (22,800 to 141,600 psi [157 to 976 MPa]), bar diameter (No. 5, 8, and 11 [No. 19, 25, and 36]), concrete side cover (1.5 to 4 in. [38 to 102 mm]), quantity of confining reinforcement in the joint region, hooked bar spacing (3 to 11 bar diameters measured center-to-center), hook bend angle (90° or 180°), placement of the hook (inside or outside the column core, and inside or outside of the column compressive region), and embedment length. Using a subset of 214 simulated exterior beam-column joints, expressions are developed to characterize the anchorage capacity of hooked bars as a function of embedment length, concrete compressive strength, bar diameter, and amount and orientation of confining reinforcement. The results of this study show that front failure plays an important role in the behavior of hooked bars, which contrasts with the findings of previous studies. The provisions in the 2014 ACI Building Code become less conservative as the concrete compressive strength and bar diameter increase. The contribution of concrete compressive strength to the anchorage capacity of hooked bars can be represented by the concrete compressive strength to the 0.29 power, in contrast to the 0.5 power currently used in the ACI 318-14 Code. Confining reinforcement, expressed as the area of confining reinforcement per confined hooked bar, provides in an incremental rather than percentage increase in the anchorage capacity of hooked bars. Confining reinforcement parallel to the straight portion of the hooked bars contributes to the anchorage capacity of both 90° and 180° hooked bars. The contribution of confining reinforcement oriented perpendicular to the straight portion of the hooked bar differs from that of confining reinforcement parallel to the straight portion of the hooked bar and may be similar to the contribution of confining reinforcement to the development and splice strength of straight bars. Hooked bars with 90° and 180° bend angles produce similar anchorage capacities and can be used interchangeably. Increasing concrete side cover from 2.5 to 3.5 in. (64 to 89 mm) does not increase the anchorage capacity of hooked bars. These observations are incorporated into a new design equation that allows for the conservative design of hooked bars at concrete strengths up to 16,000 psi and steel stresses up to 120 ksi, well above current Code limits.en_US
dc.publisherUniversity of Kansas Center for Research, Inc.en_US
dc.relation.ispartofseriesSM Report;115
dc.relation.isversionofhttps://iri.ku.edu/reportsen_US
dc.subjectAnchorageen_US
dc.subjectBeam-column jointsen_US
dc.subjectBond and developmenten_US
dc.subjectConcreteen_US
dc.subjectHigh-strength concreteen_US
dc.subjectHigh-strength steelen_US
dc.subjectHooksen_US
dc.subjectReinforcementen_US
dc.subjectReinforced concreteen_US
dc.subjectSide coveren_US
dc.subjectBend angleen_US
dc.subjectReliabilityen_US
dc.subjectVariabilityen_US
dc.titleAnchorage Strength of Conventional and High-Strength Hooked Bars in Concreteen_US
dc.typeTechnical Report
kusw.kuauthorDarwin, David
kusw.kudepartmentCivil/Environ/Arch Engineeringen_US
dc.identifier.orcidhttps://orcid.org/0000-0001-5039-3525
kusw.oapolicyThis item does not meet KU Open Access policy criteria.
dc.rights.accessrightsopenAccess


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record