Show simple item record

dc.contributor.authorTan, Changzheng
dc.contributor.authorDarwin, David
dc.contributor.authorTholen, Michael L.
dc.contributor.authorZuo, Jun
dc.date.accessioned2016-03-04T21:10:06Z
dc.date.available2016-03-04T21:10:06Z
dc.date.issued1996-05
dc.identifier.citationTan, C., Darwin, D., Tholen, M.L., Zuo, J., "Splice Strength of Epoxy-Coated High Relative Rib Area Bars," SL Report 96-2, University of Kansas Center for Research, Inc., Lawrence, KS, May 1996, 73 pp.en_US
dc.identifier.urihttp://hdl.handle.net/1808/20453
dc.description.abstractThe effect of epoxy coating on the splice strength of high relative rib area bars with and without confining transverse reinforcement is described. Test results for 47 beam splice specimens containing No. 5, No. 8, or No. 11 (16, 25 or 36 mm) bars with relative rib areas ranging from 0.101 to 0.141 and seven deformation patterns are included in the analysis. Twenty seven of the 47 beam splice tests are reported for the first time. Average coating thickness ranged from 7.1 to 16.8 mils (0.18 to 0.43 mm). Fortythree specimens were bottom-cast and four were top-cast. The test results for the high relative rib area bars are combined with 44 previous splice tests using conventional bars. Epoxy coating was found to have a much less detrimental effect on splice strength for high relative rib area bars than for conventional bars. The average splice strength ratio of coated to uncoated bars C/U is 0.89, compared to 0.74 for conventional reinforcement. C!U is approximately the same for splices with and without transverse reinforcement. The test results of the current study indicate that the development length modification factor required by the ACI Building Code (318-95) and the AASHTO Bridge Specifications (1992) can be reduced from 1.5 to 1.2 for epoxy-coated high relative rib bars.en_US
dc.publisherUniversity of Kansas Center for Research, Inc.en_US
dc.relation.ispartofseriesSL Report;96-2
dc.relation.isversionofhttps://iri.ku.edu/reportsen_US
dc.subjectBond (concrete to reinforcement)en_US
dc.subjectBridge specificationsen_US
dc.subjectBuilding codesen_US
dc.subjectDeformed reinforcementen_US
dc.subjectDevelopmenten_US
dc.subjectEpoxy coatingen_US
dc.subjectReinforcing steelsen_US
dc.subjectRelative rib areaen_US
dc.subjectSplicingen_US
dc.subjectStructural engineeringen_US
dc.titleSplice Strength of Epoxy-Coated High Relative Rib Area Barsen_US
dc.typeTechnical Report
kusw.kuauthorDarwin, David
kusw.kudepartmentCivil/Environ/Arch Engineeringen_US
dc.identifier.orcidhttps://orcid.org/0000-0001-5039-3525
kusw.oapolicyThis item does not meet KU Open Access policy criteria.
dc.rights.accessrightsopenAccess


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record