ATTENTION: The software behind KU ScholarWorks is being upgraded to a new version. Starting July 15th, users will not be able to log in to the system, add items, nor make any changes until the new version is in place at the end of July. Searching for articles and opening files will continue to work while the system is being updated.
If you have any questions, please contact Marianne Reed at mreed@ku.edu .
DETERMINING THE OPTIMUM PLACEMENT OF A PHASE CHANGE MATERIALS (PCM) THERMAL SHIELD INSIDE FRAME WALLS USING A DYNAMIC WALL SIMULATOR
dc.contributor.advisor | Medina, Mario A. | |
dc.contributor.author | Reshmeen, Silvia | |
dc.date.accessioned | 2010-01-07T23:24:12Z | |
dc.date.available | 2010-01-07T23:24:12Z | |
dc.date.issued | 2009-12-23 | |
dc.date.submitted | 2009 | |
dc.identifier.other | http://dissertations.umi.com/ku:10679 | |
dc.identifier.uri | http://hdl.handle.net/1808/5659 | |
dc.description.abstract | ABSTRACT This thesis presents the results of an experimental study to determine the optimum placement and the thermal performance of a Phase Change Materials (PCMs) thermal shield incorporated into frame wall insulation systems for the purpose of reducing space cooling load energy use in residential and commercial buildings. The performance of the walls outfitted with the PCMs thermal shields was evaluated using a dynamic wall simulator. The interior of the dynamic simulator was designed to reproduce the conditions of the exterior of a conventional residential building wall and the exterior of the dynamic simulator represented the indoor conditions of a typical residential building since the dynamic simulator was located in an air conditioned research laboratory. Measurements of heat fluxes and calculation of percentages of peak heat transfer rate reductions were evaluated for 10% and 20% PCM concentration in the thermal shields along with two control walls. The main goals of using a PCM thermal shield were to reduce peak air conditioning demand, to shift the peak load, and to conserve energy. The results of this study show that the PCM thermal shields produce greater peak heat transfer rate reductions when they are placed further away from the heat source inside of the wall cavity and are less effective when temperatures are high. The 20% PCM thermal shield was more effective than 10% PCM thermal shields. For the optimal location of the thermal shield the reductions in peak heat transfer rates were in the range of 20-25% when compared with the control walls. | |
dc.format.extent | 114 pages | |
dc.language.iso | EN | |
dc.publisher | University of Kansas | |
dc.rights | This item is protected by copyright and unless otherwise specified the copyright of this thesis/dissertation is held by the author. | |
dc.subject | Architectural engineering | |
dc.title | DETERMINING THE OPTIMUM PLACEMENT OF A PHASE CHANGE MATERIALS (PCM) THERMAL SHIELD INSIDE FRAME WALLS USING A DYNAMIC WALL SIMULATOR | |
dc.type | Thesis | |
dc.contributor.cmtemember | Glavinich, Thomas E. | |
dc.contributor.cmtemember | Young, Bryan | |
dc.thesis.degreeDiscipline | Civil, Environmental, & Architectural Engineering | |
dc.thesis.degreeLevel | M.S. | |
kusw.oastatus | na | |
kusw.oapolicy | This item does not meet KU Open Access policy criteria. | |
kusw.bibid | 7079130 | |
dc.rights.accessrights | openAccess |
Files in this item
This item appears in the following Collection(s)
-
Engineering Dissertations and Theses [1055]
-
Theses [4088]