Show simple item record

dc.contributor.advisorLunte, Craig E.
dc.contributor.authorHoque, Ehsanul
dc.date.accessioned2008-08-05T02:39:21Z
dc.date.available2008-08-05T02:39:21Z
dc.date.issued2007-12-18
dc.date.submitted2007
dc.identifier.otherhttp://dissertations.umi.com/ku:2307
dc.identifier.urihttp://hdl.handle.net/1808/4018
dc.description.abstractThis research describes the development of analytical methods based upon separation techniques coupled to microdialysis sampling for the detection of potential biomarkers of oxidative stress. The research focused on two biomarkers, glutathione and the hydroxyl radical (.OH). Microdialysis sampling was utilized for the continuous monitoring of these biomarkers in rat liver and heart. Oxidative stress was induced, causing the generation of reactive oxygen species (ROS). It was hypothesized that ROS generation would increase in biological systems due to induced oxidative stress. In one investigation, a capillary electrophoresis (CE) method with ultra-violet (UV) detection was developed employing pH-mediated stacking, an on-column preconcentration technique, to detect two forms of glutathione, reduced glutathione (GSH) and oxidized glutathione (GSSG), simultaneously in microdialysates. The detection limits necessary for measuring GSH and GSSG in microdialysates with UV detection could not be achieved without the use of pH-mediated stacking. The method was utilized to monitor glutathione in microdialysates from rat liver that was subjected to chemically induced oxidative stress using adriamycin. GSSG concentration was found to increase from the basal concentration as a result of oxidative stress, suggesting increased antioxidant activities during oxidative stress. For the indirect detection of .OH in microdialysates, a trapping agent, 4-hydroxybenzoic acid (4-HBA), was employed. Indirect determination involved the trapping of .OH by 4-HBA and then detection of the radical adduct, 3,4-dihydroxybenzoic acid (3,4-DHBA), by the developed CE-UV method. In vitro studies of .OH generation systems (e.g., UV photolysis of H2O2, the Fenton reaction, and hypoxanthine/xanthine oxidase systems with and without superoxide dismutase) demonstrated the capability of 4-HBA to trap .OH and the ability of the CE-UV method to detect 3,4-DHBA in the reaction products. Finally, an in vivo investigation was performed using CE-UV and high performance liquid chromatography (HPLC) method with electrochemical (EC) detection to detect 3,4-DHBA in microdialysates from rat heart where 4-HBA was delivered through the microdialysis probe to trap .OH. Increased generation of 3,4-DHBA was observed in microdialysates of rat heart subjected to physically induced oxidative stress (ischemia-reperfusion), suggesting increased generation of ROS during oxidative stress.
dc.format.extent202 pages
dc.language.isoEN
dc.publisherUniversity of Kansas
dc.rightsThis item is protected by copyright and unless otherwise specified the copyright of this thesis/dissertation is held by the author.
dc.subjectAnalytical chemistry
dc.subjectOxidative stress
dc.subjectBiomarkers
dc.subjectGlutathione
dc.subjectHydroxyl radicals
dc.subjectCe
dc.subjectHplc
dc.titleDevelopment of Analytical Methods Coupled to Microdialysis Sampling for Studying Biomarkers of Oxidative Stress
dc.typeDissertation
dc.contributor.cmtememberLunte, Susan M.
dc.contributor.cmtememberRivera, Mario
dc.contributor.cmtememberDunn, Robert C.
dc.contributor.cmtememberDesaire, Heather
dc.thesis.degreeDisciplineChemistry
dc.thesis.degreeLevelPH.D.
kusw.oastatusna
kusw.oapolicyThis item does not meet KU Open Access policy criteria.
kusw.bibid6599229
dc.rights.accessrightsopenAccess


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record