KUKU

KU ScholarWorks

  • myKU
  • Email
  • Enroll & Pay
  • KU Directory
    • Login
    View Item 
    •   KU ScholarWorks
    • Dissertations and Theses
    • Dissertations
    • View Item
    •   KU ScholarWorks
    • Dissertations and Theses
    • Dissertations
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Analysis of Glycopeptides by HPLC MS and Detection of Leukemic Cells by Microfluidics using Time Delayed Integration Spectral Flow Cytometry

    Thumbnail
    View/Open
    Available after: 2020-05-31 (3.821Mb)
    Issue Date
    2019-05-31
    Author
    Hu, Wenting
    Publisher
    University of Kansas
    Format
    155 pages
    Type
    Dissertation
    Degree Level
    Ph.D.
    Discipline
    Chemistry
    Rights
    Copyright held by the author.
    Metadata
    Show full item record
    Abstract
    Protein glycosylation drives many biological processes and serves as marker for disease; therefore, the development of tools to study glycosylation is an essential and growing area of research. Mass spectrometry can be used to identify both the glycans of interest and the glycosylation sites to which those glycans are attached, when proteins are proteolytically digested and their glycopeptides are analyzed by a combination of high-resolution mass spectrometry (MS) and tandem mass spectrometry (MS/MS) methods. One major challenge in these experiments is collecting the requisite MS/MS data. The digested glycopeptides are often present in complex mixtures and in low abundance, and the most commonly used approach to collect MS/MS data on these species is data-dependent acquisition (DDA), where only the most intense precursor ions trigger MS/MS. DDA results in limited glycopeptide coverage. Semi-targeted data acquisition is an alternative experimental approach that can alleviate this difficulty. However, due to the massive heterogeneity of glycopeptides, it is not obvious how to expediently generate inclusion lists for these types of analyses. To solve this problem, we developed the software tool GlycoPep MassList, which can be used to generate inclusion lists for liquid chromatography tandem-mass spectrometry (LC-MS/MS) experiments. The utility of the software was tested by conducting comparisons between semi-targeted and untargeted data-dependent analysis experiments on a variety of proteins, including IgG, a protein whose glycosylation must be characterized during its production as a biotherapeutic. When the GlycoPep MassList software was used to generate inclusion lists for LC-MS/MS experiments, more unique glycopeptides were selected for fragmentation. Generally, ∼30 % more unique glycopeptides can be analyzed per protein, in the simplest cases, with low background. In cases where background ions from proteins or other interferents are high, usage of an inclusion list is even more advantageous. The software is free and publicly accessible. In another research project, we describe a unique flow cytometer (TDI SFC) that combines the high spectral resolution of spectral flow cytometry (SFC) with a CCD operated in time-delayed integration (TDI) mode for the automated immunophenotyping of rare, low abundant cells. A microfluidic device providing 1-D focusing was used to sheath cells through a 488 nm laser excitation beam. Using epi-illumination, a spectrograph was included into the emission optical path to spectrally disperse the emission along one axis of a CCD camera. The parallel shift rate of the CCD was synchronized to the cell travel through the field-of-view, which was defined by the excitation volume. This TDI SFC format allowed the CCD shutter to remain open during signal acquisition and as such, the duty cycle was ~100% allowing for rare cells to not be missed. Fluorescent calibration beads were used to optimize synchronization of the CCD’s TDI clocking with the sheathed cell velocity, TDI SFC sensitivity, excitation power intensity, epi-illumination objective’s numerical aperture, and total integration time. TDI integrated signals of 106 counts at a signal-to-noise ratio (SNR) of 610 for beads corresponding to a load of 4×105 antibodies per bead was achieved. Additionally, we evaluated the multiplexing capabilities by performing spectral deconvolution. Finally, a proof-of-concept application was undertaken to immunophenotype rare cells, specifically leukemic cells circulating in the blood of patients with B-cell acute lymphoblastic leukemia (B-ALL) for monitoring measurable residual disease (MRD). A B-ALL cell line was stained against a leukemic marker (TdT) to successfully discriminate TdT(+) circulating leukemic cells from normal B cells at very low cell counts (≤100 cells).
    URI
    http://hdl.handle.net/1808/30204
    Collections
    • Dissertations [3958]

    Items in KU ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.


    We want to hear from you! Please share your stories about how Open Access to this item benefits YOU.


    Contact KU ScholarWorks
    785-864-8983
    KU Libraries
    1425 Jayhawk Blvd
    Lawrence, KS 66045
    785-864-8983

    KU Libraries
    1425 Jayhawk Blvd
    Lawrence, KS 66045
    Image Credits
     

     

    Browse

    All of KU ScholarWorksCommunities & CollectionsThis Collection

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Contact KU ScholarWorks
    785-864-8983
    KU Libraries
    1425 Jayhawk Blvd
    Lawrence, KS 66045
    785-864-8983

    KU Libraries
    1425 Jayhawk Blvd
    Lawrence, KS 66045
    Image Credits
     

     

    The University of Kansas
      Contact KU ScholarWorks
    Lawrence, KS | Maps
     
    • Academics
    • Admission
    • Alumni
    • Athletics
    • Campuses
    • Giving
    • Jobs

    The University of Kansas prohibits discrimination on the basis of race, color, ethnicity, religion, sex, national origin, age, ancestry, disability, status as a veteran, sexual orientation, marital status, parental status, gender identity, gender expression and genetic information in the University’s programs and activities. The following person has been designated to handle inquiries regarding the non-discrimination policies: Director of the Office of Institutional Opportunity and Access, IOA@ku.edu, 1246 W. Campus Road, Room 153A, Lawrence, KS, 66045, (785)864-6414, 711 TTY.

     Contact KU
    Lawrence, KS | Maps