Show simple item record

dc.contributor.advisorFerraro, John
dc.contributor.authorAlmohammad, Hana Ahmad Ibrahim
dc.date.accessioned2018-10-22T22:22:27Z
dc.date.available2018-10-22T22:22:27Z
dc.date.issued2016-12-31
dc.date.submitted2016
dc.identifier.otherhttp://dissertations.umi.com/ku:15018
dc.identifier.urihttp://hdl.handle.net/1808/26938
dc.description.abstractCurrently, there is no objective hearing measure used clinically that reliably assesses low frequency hearing thresholds (below a 1000 Hz or so). A new measure, the auditory nerve overlapped waveform response (ANOW), holds promise for providing more accurate assessment of low frequency hearing thresholds than currently used objective measures. However, ANOW recordings reported in the literature have been limited primarily to animal studies. This project aims to understand the nature of the ANOW response that is recorded non-invasively from humans. Three within session repeated recordings of the ANOW response using two low frequency TB stimuli (250 Hz and 500 Hz TBs) presented at 7 stimulus intensity levels were obtained from the tympanic membranes of normal hearing adult participants. ANOW’s absolute amplitude, signal-to-noise ratio (SNR), and phase locking value (PLV) measures were used in the analysis. Results revealed significantly stronger phase locking to the stimulus for 250 Hz TB stimulus compared to 500 Hz TB stimulus. Statistically significant effect of the stimulus intensity on all three measures of the ANOW response was revealed for both TB stimuli. Test retest reliability of the ANOW’s amplitude was the highest amongst the three measures, but was dependent on the stimulus intensity level. Unlike SNR measure, PLV measure is not dependent on the amplitude. The deviation from the standard approach of the PLV computation and manipulating the frequency of the TB stimulus may have biased PLV measures and affected test retest repeatability of PLV measures. Hence, developing a technique that would more accurately estimate phase synchronization between ANOW response and stimulus may reveal a new ANOW measure that is reliable across wide range of stimulus intensity levels.
dc.format.extent117 pages
dc.language.isoen
dc.publisherUniversity of Kansas
dc.rightsCopyright held by the author.
dc.subjectHealth sciences
dc.subjectAudiology
dc.subjectANOW
dc.subjectcochlear microphonics
dc.subjectelectrocochleography
dc.subjectlow frequency hearing
dc.subjectphase locking
dc.titleANOW RESPONSE RECORDED VIA ELECTROCOCHLEOGRAPHY IN NORMAL HEARING ADULTS
dc.typeDissertation
dc.contributor.cmtememberChertoff, Mark
dc.contributor.cmtememberDiaz, Francisco
dc.contributor.cmtememberBrumberg, Jonathan
dc.contributor.cmtememberKokkinakis, Kostas
dc.thesis.degreeDisciplineHearing and Speech
dc.thesis.degreeLevelPh.D.
dc.identifier.orcid
dc.rights.accessrightsopenAccess


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record