    JavaScript is disabled for your browser. Some features of this site may not work without it.

    The Design and Validation of a Force and Bending Moment Sensing Device

    Thumbnail
    View/Open
    Hodes_ku_0099M_14316_DATA_1.pdf (3.282Mb)
    Issue Date
    2015-12-31
    Author
    Hodes, Alexander
    Publisher
    University of Kansas
    Format
    186 pages
    Type
    Thesis
    Degree Level
    M.S.
    Discipline
    Bioengineering
    Rights
    Copyright held by the author.
    Metadata
    Show full item record
    Abstract
    Shoulder dystocia (SD) is a serious obstetric emergency in which an infant’s shoulder becomes blocked by the mother’s pubic symphasis and the infant is unable to be delivered. In these instances, the infant must be delivered hastily, yet this hurried extraction may lead to an increase in clinician-applied forces. Injury risk is as high as 10% of all SD cases as it is shown that excessive force applied on the head and neck of the infant can lead to birthing injuries, specifically brachial plexus injuries (BPI) [2-4]. Several groups speculate that the direction of force applied to an infant head and neck is important in determining the amount of brachial plexus stretch of an infant [1, 5]. In this study we discuss the development and validation of a force and bending moment sensing glove that will be used to investigate clinician-applied forces. The developed glove uses an Arduino microcontroller, pressure sensors, inertial sensors, and magnetic sensors to determine orientation and forces sensed by the device. In order to ensure the glove system performed correctly, our device was validated against external systems to assess accuracy of the developed glove. The system was first validated for orientation by placing electromagnetic sensors from an external motion detection system (accuracy <0.5°) on a hand mannequin along with the inertial and magnetic sensors (IMUs) of the developed device. Inertial and electromagnetic sensors were placed on the back of each fingertip as well as the hand. After comparing 14 different hand orientations, the average root-mean-square error (RMSE) between calculated Euler angles from the glove device and electromagnetic sensors was less than 16° in any direction.
    URI
    http://hdl.handle.net/1808/25636
    Collections
    • Theses [3743]

    Items in KU ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.


    We want to hear from you! Please share your stories about how Open Access to this item benefits YOU.


    Contact KU ScholarWorks
    785-864-8983
    KU Libraries
    1425 Jayhawk Blvd
    Lawrence, KS 66045
    785-864-8983

    KU Libraries
    1425 Jayhawk Blvd
    Lawrence, KS 66045
    Image Credits
     

     

    Browse

    All of KU ScholarWorksCommunities & CollectionsThis Collection

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Contact KU ScholarWorks
    785-864-8983
    KU Libraries
    1425 Jayhawk Blvd
    Lawrence, KS 66045
    785-864-8983

    KU Libraries
    1425 Jayhawk Blvd
    Lawrence, KS 66045
    Image Credits
     

     

    The University of Kansas
      Contact KU ScholarWorks
    Lawrence, KS | Maps
     
    • Academics
    • Admission
    • Alumni
    • Athletics
    • Campuses
    • Giving
    • Jobs

    The University of Kansas prohibits discrimination on the basis of race, color, ethnicity, religion, sex, national origin, age, ancestry, disability, status as a veteran, sexual orientation, marital status, parental status, gender identity, gender expression and genetic information in the University’s programs and activities. The following person has been designated to handle inquiries regarding the non-discrimination policies: Director of the Office of Institutional Opportunity and Access, IOA@ku.edu, 1246 W. Campus Road, Room 153A, Lawrence, KS, 66045, (785)864-6414, 711 TTY.

     Contact KU
    Lawrence, KS | Maps