ATTENTION: The software behind KU ScholarWorks is being upgraded to a new version. Starting July 15th, users will not be able to log in to the system, add items, nor make any changes until the new version is in place at the end of July. Searching for articles and opening files will continue to work while the system is being updated. If you have any questions, please contact Marianne Reed at mreed@ku.edu .

Show simple item record

dc.contributor.authorFischer, Kenneth J.
dc.contributor.authorManson, T. T.
dc.contributor.authorPfaeffle, H. James
dc.contributor.authorTomaino, M. M.
dc.contributor.authorWoo, S. L-Y
dc.date.accessioned2005-03-24T17:29:06Z
dc.date.available2005-03-24T17:29:06Z
dc.date.issued2001-03
dc.identifier.citationFischer, KJ; Manson, TT; Pfaeffle, HJ; Tomaino, MM; Woo, SLY. A method for measuring joint kinematics designed for accurate registration of kinematic data to models constructed from CT data. JOURNAL OF BIOMECHANICS. March 2001. 34(3):377-383.
dc.identifier.otherISI:000167482500012
dc.identifier.otherhttp://www.sciencedirect.com/science/journal/00219290
dc.identifier.urihttp://hdl.handle.net/1808/255
dc.description.abstractA method for measuring three-dimensional kinematics that incorporates the direct cross-registration of experimental kinematics with anatomic geometry from Computed Tomography (CT) data has been developed. Plexiglas registration blocks were attached to the bones of interest and the specimen was CT scanned. Computer models of the bone surface were developed from the CT image data. Determination of discrete kinematics was accomplished by digitizing three pre-selected contiguous surfaces of each registration block using a three-dimensional point digitization system. Cross-registration of bone surface models from the CT data was accomplished by identifying the registration block surfaces within the CT images. Kinematics measured during a biomechanical experiment were applied to the computer models of the bone surface. The overall accuracy of the method was shown to be at or below the accuracy of the digitization system used. For this experimental application, the accuracy was better than +/-0.l mm for position and 0.1 degrees for orientation for linkage digitization and better than +/- 0.2 mm and +/- 0.2 degrees for CT digitization. Surface models of the radius and ulna were constructed from CT data, as an example application. Kinematics of the bones were measured for simulated forearm rotation. Screw-displacement axis analysis showed 0.1 mm (proximal) translation of the radius (with respect to the ulna) from supination to neutral (85.2 degrees rotation) and 1.4 mm (proximal) translation from neutral to pronation (65.3 degrees rotation). The motion of the radius with respect to the ulna was displayed using the surface models. This methodology is a useful tool for the measurement and application of rigid-body kinematics to computer models. (C) 2001 Elsevier Science Ltd. All rights reserved.
dc.format.extent228404 bytes
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherELSEVIER SCIENCE LTD
dc.relation.isversionofhttp://www.ncbi.nlm.nih.gov/pubmed/11182130
dc.subjectKinematic measurements
dc.subjectForearm motion
dc.subjectComputed tomography
dc.subjectGeometrical registration
dc.subjectComputer visualization
dc.titleA method for measuring joint kinematics designed for accurate registration of kinematic data to models constructed from CT data
dc.typeArticle
kusw.kuauthorFischer, Kenneth J.
dc.rights.accessrightsopenAccess


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record