We present a measurement of the W boson mass using data collected by the DØ experiment at the Fermilab Tevatron during 1994–1995. We identify W bosons by their decays to eν final states where the electron is detected in a forward calorimeter. We extract the W boson mass M(W) by fitting the transverse mass and transverse electron and neutrino momentum spectra from a sample of 11 089 W⃗ eν decay candidates. We use a sample of 1687 dielectron events, mostly due to Z⃗ ee decays, to constrain our model of the detector response. Using the forward calorimeter data, we measure M(W)=80.691±0.227 GeV. Combining the forward calorimeter measurements with our previously published central calorimeter results, we obtain M(W)=80.482±0.091 GeV.
Description
This is the publisher's version, also available electronically from http://journals.aps.org/prd/abstract/10.1103/PhysRevD.62.092006.
Date
2000-10-12
Journal Title
Journal ISSN
Volume Title
Publisher
American Physical Society
Research Projects
Organizational Units
Journal Issue
Keywords
Citation
B. Abbott et al. ((DØ Collaboration)). (2000). "Measurement of the W boson mass using large rapidity electrons." Physical Review D, 62(9):092006. http://dx.doi.org/10.1103/PhysRevD.62.092006.